Display and control panel AMS 348i
46
AMS 348
i
Leuze electronic GmbH + Co. KG
Note!
The rear cover of this manual includes a fold-out page with the complete menu structure. It
describes the menu items in brief.
A detailed description of the individual parameters can be found in the description of the
PROFINET GSD modules (see chapter 9.9.2 "Overview of the GSD modules").
Attention!
If parameters are changed via the display during bus operation, the AMS 348
i
is separated
from the PROFINET at the moment parameter enabling is activated via the display. Param
-
eters set by the PROFINET are moved to the background, and changes to parameters can
be made via the display. When parameter enabling is exited, the AMS 348
i
is automatically
reconnected to the PROFINET. Upon connection to the PROFINET, the AMS 348
i
receives
all parameters from the PROFINET Controller (PLC).
Changes made via the display are overwritten!
Device settings for operating the AMS 348
i
on the PROFINET are managed and configured
exclusively by the PROFINET controller (PLC).
IO1 LSR PLB
LNK0
IO2 TMP ATT
LNK1
ERR
+ 87.000m
Status and measurement data - main menu
• Display of status, warning and error messages.
• Status overview of the switching inputs/outputs
• Bar graph for the received signal level.
• Link
• Measurement value
No entries can be made via the display.
See "Indicators in the display" on page 40.
Parameter
Parameter handling
PROFINET
Position value
I/O
Other
Parameter - main menu
• Configuration of the AMS.
See "Parameter menu" on page 47.
Language selection
o Deutsch
o English
o Español
o Français
o Italiano
Language selection - main menu
• Selection of the display language.
See "Language selection menu" on page 51.
Service
Status messages
Diagnosis
Expanded diagnosis
Service - main menu
• Display of status messages.
• Display of diagnostic data.
No entries can be made via the display.