PROFINET interface
84
AMS 348
i
Leuze electronic GmbH + Co. KG
Note!
Behavior of the AMS 348
i
with laser ON/OFF:
If the laser light spot is positioned on the reflector when the laser diode is switched on, the
AMS 348
i
returns valid measurement values after approx. 330ms.
If the laser light spot is not positioned on the reflector when the laser diode is switched on,
the
AMS 348
i
cannot calculate any distance values. If the laser beam hits the reflector at a
later point in time while switched on, the
AMS 348
i
returns valid measurement values after
the following time span:
t = (measurement distance / 20m) sec.
Example:
Aisle change of a high-bay storage device during which the laser diode is
not switched off while traveling around curves.
Measurement distance 100m –> t = 5sec., measurement distance 200m –
> t = 10sec.
Input data
Output data
Output
Hardware (ERR)
If a hardware error is diagnosed,
the output is set.
1.7 Bit
0 = OFF
1 = ON
0
–
5a
Pseudodynamic output
If bit 0.0 is set in the output data,
the output is set.
2.1 Bit
0 = OFF
1 = ON
0
–
Input
Preset
The HW input is used as the pre
-
set teach input (valid for static or
dynamic preset).
Laser
The HW input is used as laser
OFF.
3.0
…
3.2
unsign
8Bit
000 =HW input no func
-
tion
001 =HW input as preset
teach function
010 =HW input as laser
OFF function
000
–
5a
Parameter length: 4 bytes
c
d
Input data
Description
Rel.
addr
.
Data
type
Value
Default Unit
CR to
module
Metr. Inch
State
Signal state of the input or output. 0.0 Bit
0: Input/output inactive
at signal level
1: Input/output active at
signal level
–
–
–
Input data length: 1 byte