PROFINET interface
100
AMS 348
i
Leuze electronic GmbH + Co. KG
9.9.3.16 Module 16: Velocity status
PROFINET module identifier
Module ID
1016
Submodule ID
1
Description
This module supplies various velocity measurement status information to the PROFINET
master.
Parameter
None
Input data
Input data
Description
Rel.
addr
.
Data
type
Value
Default Unit
CR to
module
Metr. Inch
Velocity
measure
-
ment error
Signals that no valid velocity could
be ascertained.
1.0 Bit
0: OK
1: Error
–
–
–
Movement
status
Signals whether a movement
> 0.1 m/s is currently being
detected.
1.1 Bit
0: No movement
1: Movement
–
–
–
Direction of
movement
When the movement status is
activated, this bit indicates the
direction.
1.2 Bit
0: Positive direction
1: Negative direction
–
–
–
Velocity limit
value status
1
Signals that limit value 1 has been
exceeded.
1.3 Bit
0: Limit value
maintained
1: Limit value violated
–
–
11c
Velocity limit
value status
2
Signals that limit value 2 has been
exceeded.
1.4 Bit
0: Limit value
maintained
1: Limit value violated
–
–
12c
Velocity limit
value status
3
Signals that limit value 3 has been
exceeded.
1.5 Bit
0: Limit value
maintained
1: Limit value violated
–
–
13c
Velocity limit
value status
4
Signals that limit value 4 has been
exceeded.
1.6 Bit
0: Limit value
maintained
1: Limit value violated
–
–
14c
Dynamic
velocity limit
value status
Signals that the dynamic limit
value has been exceeded.
1.7 Bit
0: Limit value
maintained
1: Limit value violated
–
–
15bd
Velocity
comparison
Limit value 1
Signals whether the current
velocity is compared with this limit
value.
0.3 Bit
0: Comparison not
active
1: Comparison active
–
–
–
a
b
c
d
e
f
g
h
i