PROFINET interface
94
AMS 348
i
Leuze electronic GmbH + Co. KG
Input data
None
Output data
None
Limit
value 1
range start
The velocity limit value is moni
-
tored beginning at this position. 5…8
sign
32 bit
-999999 … +999999
0
mm
in/
100 –
Limit
value 1
range end
The velocity limit value is moni
-
tored up to this position.
9
…
12
sign
32 bit
-999999 … +999999
0
mm
in/
100 –
Parameter length: 13 bytes
e