PROFINET interface
102
AMS 348
i
Leuze electronic GmbH + Co. KG
9.9.3.17 Module 18: Other
PROFINET module identifier
Module ID
1018
Submodule ID
1
Description
General operating parameters such as display language, lighting and contrast, password,
heating control, etc. are set in this module.
Parameter
Input data
None
Output data
None
Parameter
Description
Rel.
addr.
Data
type
Value
Default Unit
CR to
module
Metr. Inch
Language
selection
Language selection for the dis
-
play.
A language preselected via the
display is overwritten by this
parameter.
0.0
…
0.2
Bit
000=0: English
001=1: German
010=2: Italian
011=3: Spanish
100=4: French
0
–
–
Display illu
-
mination
Off after 10min. or always on.
0.3
Bit
0: Off after 10min.
1: Always on
0
–
–
Display
contrast
Contrast setting of the display.
The contrast changes under
extreme ambient temperatures
and can be adjusted with this
parameter.
0.4
…
0.5
Bit
000=0: Weak
001=1: Medium
010=2: Strong
1
–
–
Password
protection
Password protection on/off
0.7
Bit
0: OFF
1: ON
0
–
–
Password
Specifies the password.
Password protection must be on. 1…2
unsign
16 bit
0000 … 9999
0000
–
–
Heating
control
Defines a switch-on/switch-off
range for the heating control. The
extended switch-on/switch-off
range for heating may provide a
remedy in the event of conden
-
sation problems. Due to the lim
-
ited heating capacity, it cannot
be guaranteed that no conden
-
sation will form on the optics in
the extended switch-on/switch-
off range.
This parameter is available as
standard, but functions only for
devices with integrated heating
(AMS 348
i
… H).
3.0
Bit
0 = Standard
Tamb. < 10°C: heating
on
Tamb. > 15°C: heating
off
1 = Extended
T
amb.
< 30°C: heating on
T
amb.
> 35°C: heating off
0
–
–
Parameter length: 4 bytes
a
b
c
d
e
f