3.4
Code table
How to read the code table:
Column
Abbreviation
Meaning
Code
C0168
1
2
¼
8
Code C0168
Subcode 1 of code C0168
Subcode 2 of code C0168
¼
Subcode 8 of code C0168
[C0156] Parameter value of code can only be changed when controller is inhibited.
LCD
Keypad LCD
Lenze
Factory setting of the code
g
Display code (can only be displayed)
* The column ”Info” contains more information
Selection 1
{1 %}
99 Minimum value
{smallest step/unit}
maximum value
Info
Additional information on code
Code
LCD
Possible settings
Info
o
Lenze
Selection
o
[C0002] Par load
0
Load parameter set
•
Parameter set1 is automatically loaded after every
mains connection.
0
Load factory setting into RAM
1
Load parameter set 1 into the RAM
C0003 Par save
0
Save parameter set
0
Saving completed
1
Non-volatile saving of parameter set 1
C0004 Op display
56
Keypad operating display
•
Keypad will indicate selected code in the operating
level if no other status indications of C0183 are active.
All available codes
[C0006] Op mode
à
Operating mode of motor control
à
depending on C0086
•
Change of C0086 resets value to the assigned default
setting
•
Change of C0006 sets C0086 = 0!
•
ESC (
Extended Speed Control
):
Speed control with incread speed steadiness for
operation with incremental encoder only (not resolver!)
.
2
Servo async Y
Servo control asynchronous motors in star connection
3
Servo PM-SM Y
Servo control snychronous motors in star connection
22
Servo async
Servo control asynchronous motors in delta connection
31
ASM Y - ESC
Servo control asynchronous motors in star connection,
ESC
32
PM-SM Y - ESC
Servo control synchronous motors in star connection, ESC
33
ASM - ESC
Servo control asynchronous motors in delta connection,
ESC
C0009 LECOM address
1
LECOM controller address
(bus device number for operation via interface)
•
10, 20, ..., 90 reserved for broadcast to device groups
for RS232, RS485, fibre optics.
1
{1}
99
efesotomasyon.com - Lenze