OH7 - Motor temperature monitoring (adjustable)
This function monitors the process.
No. Monitoring function
Display System variable
TRIP
Message Warning
Off
057 Motor temperature (adjustable)
OH7
MCTRL_bMotorTempGreaterC0121_b
•
ü
•
Default setting
ü
Setting possible
This monitoring function sends a warning before the controller is switched off because of a TRIP
(OH3) using the function “Motor temperature (fixed)”.
•
Thus, the process can be influenced to avoid a switch-off of the controller at an inconvenient
time.
•
Additionally, fans which would cause an unacceptable noise in continuous operation, can also
be switched on and off.
MCTRL_bMotorTempGreaterC0121_b
is derived from a comparator with hysteresis.
•
The threshold can be set under C0121:
Code
LCD
Possible settings
IMPORTANT
o
Lenze
Selection
C0121 OH7 limit
150
Temperature threshold prewarning
motor temperature “TMot > C0121”
(error OH7)
45
{1 °C}
150
•
The hysteresis is 15 K (fixed), i.e. the monitoring is reset at 15 K below the threshold set.
•
The response is set under C0854:
Code
LCD
Possible settings
IMPORTANT
o
Lenze
Selection
C0584 MONIT OH7
à
Configuration monitoring
à
depending on C0086
2
Warning
3
Off
•
Please also see the corresponding notes in the chapter “Motor temperature monitoring
(fixed)”.