9300 Servo PLC
System blocks
2.7
DCTRL_DriveControl
2-23
L
ServoPLC EN 2.0
2.7.5
Controller inhibit (CINH)
This function sets “Controller inhibit (CINH)”, i.e. the power stages are inhibited and all
speed/current/position controllers will be reset.
•
This function can be controlled via the following six inputs (OR linked):
– Terminal X5/28 (FALSE = controller disable)
– Control word
CAN1_wDctrlCtr
of SB
CAN1_IN
– Control word
AIF_wDctrlCtrl
of SB
AIF1_IN
– Control word C0135, bit 9
– System variable
DCTRL_bCInh1_b
(TRUE = Set controller inhibit)
– System variable
DCTRL_bCInh2_b
(TRUE = Set controller inhibit)
•
C0136/1 displays the control word C0135
2.7.6
TRIP set (TRIP-SET)
This function sets “TRIP” and sets an “External error” (error message “EEr”).
•
This function can be controlled via the following four inputs (OR linked):
– Control word
CAN1_wDctrlCtr
of SB
CAN1_IN
– Control word
AIF_wDctrlCtrl
of SB
AIF1_IN
– Control word C0135, bit 10
– System variable
DCTRL_bTripSet_b
(TRUE = set TRIP)
•
C0136/1 displays the control word C0135
•
The response to TRIP can be set under C0581:
Code
LCD
Possible settings
Info
o
Lenze
Selection
o
C0581 MONIT Eer
0
Configuration monitoring:
External error
0
TRIP
1
Message
2
Warning
3
Off
2.7.7
TRIP reset (TRIP-RESET)
This function resets a TRIP as soon as the error has been eliminated. If the cause of the fault is still
active, there is no reaction.
•
This function can be controlled via the following four inputs (OR linked):
– Control word
CAN1_wDctrlCtr
of SB
CAN1_IN
– Control word
AIF_wDctrlCtrl
of SB
AIF1_IN
– Control word C0135, bit 11
– System variable
DCTRL_bTripReset_b
Note!
The function can only be performed by a FALSE-TRUE transition of the signal resulting from the OR
operation!
•
A FALSE-TRUE transition cannot occur if TRUE is assigned to one of the inputs!
•
C0136/1 displays the control word C0135