9300 Servo PLC
Appendix
3-38
L
ServoPLC EN 2.0
Code
Info
Possible settings
LCD
Code
Info
Selection
Lenze
LCD
C2377 XCAN2 Mask
AIF-CAN: XCAN2_OUT mask
0
{hex}
FFFF
1
FFFF
Mask for process output word 1
2
FFFF
Mask for process output word 2
3
FFFF
Mask for process output word 3
4
FFFF
Mask for process output word 4
C2378 XCAN3 Mask
AIF-CAN: XCAN3_OUT mask
0
{hex}
FFFF
1
FFFF
Mask for process output word 1
2
FFFF
Mask for process output word 2
3
FFFF
Mask for process output word 3
4
FFFF
Mask for process output word 4
C2382 XCAN Conf. CE
AIF-CAN: Monitoring configuration
0
Off
1
Controller inhibit
2
QSP
1
0
XCAN1_IN (no telegram received)
2
0
CAN2_IN (no telegram received)
3
0
XCAN3_IN (no telegram received)
4
0
Bus off
5
0
Life Guarding Event
C2500
Temporary codes (see chapter 3.4.1)
0
{1}
65535
1
0
%MW 0
...
...
...
255
0
%MW 254
C2501
Temporary codes (see chapter 3.4.1)
0
{1}
65535
1
0
%MW 255
...
...
...
255
0
%MW 509
3.4.1
Temporary codes
Codes C2500 and C2501 are temporary codes, i.e. their data
•
do not use any EEPROM memory space.
•
cannot be saved in the parameter set of the unit using C0003 = 1.
•
will be lost after mains disconnection or power failure.
•
are linked with the PLC flag area.
•
Temporary codes should be used for parameters which are accessed during a switch-on
cycle of the PLC.
•
It is also possible to directly access the flag are of the PLC (e.g via HMI) without having to
create a variable.