9300 Servo PLC
Appendix
3-14
L
ServoPLC EN 2.0
Code
Info
Possible settings
LCD
Code
Info
Selection
Lenze
LCD
C0032 FCODE gearbox
1
Freely configurable codes (absolute analog signals)
•
FCODE_nC32_a (gear factor numerator)
-32767
{1}
32767
C0034 Mst current
0
Analog input AIN1:
Selection: Master voltage/master current for setpoint
selection
0
-10 V ... + 10 V
1
+4 mA ... +20 mA
2
-20 mA ... +20 mA
C0037 Set-value rpm
0
Freely configurable code (absolute speed signals)
•
FCODE_nC37_a (setpoint selection in rpm)
-16000
{1 rpm}
16000
C0040 Ctrl enable
1
Controller inhibit
•
Write code: Enable/inhibit controller
•
Read code: Read controller status
0
Controller inhibit
1
Controller enable
C0042 DIS: QSP
g
Status quick stop (QSP)
0
QSP not active
1
QSP active
C0043 Trip reset
0
Trip reset
0
Trip reset (current TRIP reset)
1
Error occurred (TRIP is active)
C0050 MCTRL-NSET2
g
Value n
set
at speed controller input (nNsetIn_a)
-100.00
{0.01 %}
100.00
C0051 MCTRL-NACT
g
Actual speed
-30000
{1 rpm}
30000
C0052 MCTRL Vmot
g
Motor voltage
0
{1 V}
800
C0053 VDC-VOLTAGE
g
DC-bus voltage
0
{1 V}
900
C0054 Imot
g
Motor current
0.0
{0.1 A}
500.0
C0056 MCTRL-MSET2
g
Torque setpoint (nMSetIn_a)
-100.00
{0.01 %}
100.00
C0057 Max Torque
g
Maximum possible torque of the drive configuration
•
depending on C0022, C0086
0.0
{0.1 Nm}
500.0
C0058 Rotor diff
0.0
Zero phase of the rotor for synchronous motors (C0095)
-180.0
{0.1
_
}
179.9
C0059 Mot pole no.
g
Pole pair number of the motor
1
{1}
50
C0060 Rotor pos
g
Current rotor position
•
1 turn = 2048 inc
0
{1}
2047
C0061 Heatsink temp
g
Heatsink temperature
0
{1 °C}
100
C0063 Mot temp
g
Motor temperature
0
{1 °C}
200
C0064 Utilization
g
Controller load I x t during the last 180 Sekunden
•
C0064 >100 % releases Trip OC5
•
Trip reset is possible only if C0064 < 95 %
0
{1 %}
150