9300 Servo PLC
System blocks
2.3
AIF3_IO_AutomationInterface
2-13
L
ServoPLC EN 2.0
2.3.2
Outputs_AIF3
Automation interface (module number 43)
This SB is used as interface for output signals (e.g. setpoint/actual value) from attached fieldbus
modules (e. g. INTERBUS, PROFIBUS-DP).
•
The process image is
– created every 10 ms.
– created in an interval task within the time set for this task.
– read at the beginning of the task and written at its end.
Tip!
Please observe the corresponding Operating Instructions for the fieldbus module that is plugged in.
Outputs_AIF3
Automation
Interface
...
Byte
1
Byte
2
Byte
3
Byte
4
Byte
5
Byte
6
Byte
7
Byte
8
...
16 Bit
LowWord
16 Bit
HighWord
16 Bit
16 binary
signals
16 Bit
16 binary
signals
AIF3_nOutW2_a
AIF3_nOutW1_a
AIF3_bFDO0_b
AIF3_bFDO15_b
AIF3_bFDO16_b
AIF3_bFDO31_b
16 Bit
16 Bit
AIF3_nOutW4_a
AIF3_dnOutD1_p
AIF3_nOutW3_a
Fig. 2-6
Outputs_AIF3
Variable name
Data type
Signal type
Address
DIS
DIS format
Note
AIF3_nOutW1_a
%QW43.0
AIF3_nOutW2_a
Integer
analog
%QW43.1
AIF3_nOutW3_a
Integer
analog
%QW43.2
AIF3_nOutW4_a
%QW43.3
AIF3_bFDO0_b
%QX43.0.0
...
...
AIF3_bFDO15_b
Bool
binary
%QX43.0.15
AIF3_bFDO16_b
Bool
binary
%QX43.1.0
...
...
AIF3_bFDO31_b
%QX43.1.15
AIF3_dnOutD1_p
Double-integer
position
%QD43.0