Table 1. Memory module installation rules for servers with one microprocessor
CPU1 DIMM
A1
A2
B1
B2
C1
C2
D1
D2
1 DIMM
X
2 DIMMs
X
X
4 DIMMs
X
X
X
X
8 DIMMs
X
X
X
X
X
X
X
X
The following table provides information about the memory module installation rules for servers that have
two microprocessors (CPU1 and CPU2) installed. The “X” mark indicates the memory slots into which the
memory modules should be installed in different situations.
Table 2. Memory module installation rules for servers with two microprocessors
CPU1 DIMM
CPU2 DIMM
A1
A2
B1
B2
C1
C2
D1
D2
A1
A2
B1
B2
C1
C2
D1
D2
2 DIMMs
X
X
4 DIMMs
X
X
X
X
8 DIMMs
X
X
X
X
X
X
X
X
16 DIMMs
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
The following section explains the memory module installation rules in independent mode, mirroring mode,
sparing mode, and lockstep mode.
Memory module installation order in independent mode
In independent mode, the RAS features are not available. For more information about the RAS features,
refer to the related section in “Features” on page 7.
Notes:
• All memory modules to be installed must be the same type.
• When you install memory modules with different capacity, install the memory module that has the
highest capacity first.
The following table explains the memory module installation order for servers that have only one
microprocessor (CPU1) installed.
Table 3. Memory module installation order in independent mode for servers with one microprocessor
CPU1 DIMM
A1
A2
B1
B2
C1
C2
D1
D2
DIMM installation order
1
5
2
6
3
7
4
8
The following table explains the memory module installation order for servers that have two microprocessors
(CPU1 and CPU2) installed.
Table 4. Memory module installation order in independent mode for servers with two microprocessors
CPU1 DIMM
CPU2 DIMM
A1
A2
B1
B2
C1
C2
D1
D2
A1
A2
B1
B2
C1
C2
D1
D2
DIMM installation order
1
9
3
11
5
13
7
15
2
10
4
12
6
14
8
16
62
ThinkServer RD350 User Guide and Hardware Maintenance Manual
Содержание ThinkServer RD350
Страница 1: ...ThinkServer RD350 User Guide and Hardware Maintenance Manual Machine Types 70D6 70D7 70D8 and 70D9 ...
Страница 14: ...xii ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 20: ...6 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 52: ...38 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 66: ...52 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 148: ...134 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 158: ...144 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 169: ... Low power memory states Appendix A Notices 155 ...
Страница 170: ...156 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 175: ......
Страница 176: ......