2. Prepare your server. See “Removing or extending the server from the rack cabinet” on page 55.
3. Remove the server cover. See “Removing the server cover” on page 55.
4. Remove the cooling shroud. See “Removing and reinstalling the cooling shroud” on page 58.
5. Locate the hot-swap hard-disk-drive backplane. See “Server components” on page 23.
6. Remove all the installed hot-swap hard disk drives and dummy trays (if any) from the hard-disk-drive
bays. See “Installing or replacing a hot-swap hard disk drive” on page 104.
7. Record the cable connections on the backplane and then disconnect all the cables from the backplane.
8. Press the two latches
1
in the direction as shown until the latches are disengaged from the chassis.
Carefully lift the backplane straight up a little bit so that the small hooks on the chassis are aligned with
the corresponding holes in the backplane. Then, move the backplane to the rear of the chassis to
release the backplane from the hooks.
Figure 91. Removing the hot-swap hard-disk-drive backplane
9. Touch the static-protective package that contains the new hot-swap hard-disk-drive backplane to any
unpainted surface on the outside of the server. Then, remove the new backplane from the package.
Note:
Carefully handle the backplane by its edges.
Chapter 6
.
Replacing hardware
117
Содержание ThinkServer RD350
Страница 1: ...ThinkServer RD350 User Guide and Hardware Maintenance Manual Machine Types 70D6 70D7 70D8 and 70D9 ...
Страница 14: ...xii ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 20: ...6 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 52: ...38 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 66: ...52 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 148: ...134 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 158: ...144 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 169: ... Low power memory states Appendix A Notices 155 ...
Страница 170: ...156 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Страница 175: ......
Страница 176: ......