2. If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, re-enable
the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
3. If problem persists, Power cycle the node from management console.
4. Reset IMM to default settings.
5. Reset UEFI to default settings.
6. Reflash IMM and UEFI firmware.
7. (Trained Service technician only) Replace system board.
•
W.58001 [W.58001] The PFA Threshold limit (correctable error logging limit) has been exceeded on
DIMM number % at address %. MC5 Status contains % and MC5 Misc contains %.
Explanation:
DIMM PFA Threshold Exceeded
Severity
Error
User Response
Complete the following steps:
1. If the node has recently been installed, moved, serviced, or upgraded, verify that the DIMM
is properly seated and visually verify that there is no foreign material in any DIMM connector
on that memory channel. If either of these conditions is found, correct and retry with the same
DIMM. (Note: Event Log may contain a recent 00580A4 event denoting detected change in
DIMM population that could be related to this problem.)
2. Check IBM support site for an applicable firmware update that applies to this memory error. The
release notes will list the known problems the update addresses.
3. If the previous steps do not resolve the problem, at the next maintenance opportunity, replace
the affected DIMM (as indicated by LightPath and/or failure log entry).
4. If PFA re-occurs on the same DIMM connector, swap the other DIMMs on the same memory
channel one at a time to a different memory channel or Processor. (check service information for
this product/Install guide for population requirements for sparing/paring modes). If PFA follows a
moved DIMM to any DIMM connector on the different memory channel, replace the moved DIMM.
5. Check IBM support site for an applicable Service Bulletins (Service bulletins) that applies to this
memory error. (Link to IBM support service bulletins)
6. (Trained service technician only) If problem continues to re-occur on the same DIMM connector,
inspect DIMM connector for foreign material and remove, if found. If connector is damaged,
replace system board.
7. (Trained service technician only) Remove affected Processor and inspect Processor socket pins
for damaged or mis-aligned pins. If damage is found or Processor is an upgrade part, replace
system board.
8. (Trained Service technician only) Replace affected processor.
9. (Trained Service technician only) Replace system board.
•
W.58007 [W.58007] Invalid memory configuration (Unsupported DIMM Population) detected. Please
verify memory configuration is valid.
Explanation:
Unsupported DIMM Population
Severity
420
Lenovo System x3250 M4 Installation and Service Guide
Содержание System x3250 M4
Страница 1: ...Lenovo System x3250 M4 Installation and Service Guide Machine Type 2583 ...
Страница 6: ...iv Lenovo System x3250 M4 Installation and Service Guide ...
Страница 74: ...60 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 98: ...84 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 136: ...122 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 418: ...404 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 596: ...582 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 604: ...Taiwan BSMI RoHS declaration 590 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 612: ...598 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 613: ......
Страница 614: ......