Table 35. Events that automatically notify Support (continued)
Event ID
Message String
Automatically
Notify Support
806f010c-2003ffff
Uncorrectable error detected for
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 3)
Yes
806f010c-2004ffff
Uncorrectable error detected for
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 4)
Yes
806f010c-2581ffff
Uncorrectable error detected for
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (All DIMMS)
Yes
806f010d-0400ffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 0)
Yes
806f010d-0401ffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 1)
Yes
806f010d-0402ffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 2)
Yes
806f010d-0403ffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 3)
Yes
806f0207-0301ffff
[ProcessorElementName] has Failed with FRB1/BIST
condition. (CPU 1)
Yes
806f020d-0400ffff
Failure Predicted on drive [StorageVolumeElementName]
for array [ComputerSystemElementName]. (Drive 0)
Yes
806f020d-0401ffff
Failure Predicted on drive [StorageVolumeElementName]
for array [ComputerSystemElementName]. (Drive 1)
Yes
806f020d-0402ffff
Failure Predicted on drive [StorageVolumeElementName]
for array [ComputerSystemElementName]. (Drive 2)
Yes
806f020d-0403ffff
Failure Predicted on drive [StorageVolumeElementName]
for array [ComputerSystemElementName]. (Drive 3)
Yes
806f050c-2001ffff
Memory Logging Limit Reached for
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 1)
Yes
806f050c-2002ffff
Memory Logging Limit Reached for
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 2)
Yes
806f050c-2003ffff
Memory Logging Limit Reached for
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 3)
Yes
806f050c-2004ffff
Memory Logging Limit Reached for
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 4)
Yes
806f050c-2581ffff
Memory Logging Limit Reached for
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (All DIMMS)
Yes
806f060d-0400ffff
Array [ComputerSystemElementName] has failed. (Drive
0)
Yes
806f060d-0401ffff
Array [ComputerSystemElementName] has failed. (Drive
1)
Yes
Appendix A. Integrated Management Module II (IMM2) error messages
205
Содержание System x3250 M4
Страница 1: ...Lenovo System x3250 M4 Installation and Service Guide Machine Type 2583 ...
Страница 6: ...iv Lenovo System x3250 M4 Installation and Service Guide ...
Страница 74: ...60 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 98: ...84 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 136: ...122 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 418: ...404 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 596: ...582 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 604: ...Taiwan BSMI RoHS declaration 590 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 612: ...598 Lenovo System x3250 M4 Installation and Service Guide ...
Страница 613: ......
Страница 614: ......