Page 4
SPECIFICATIONS CHA161853
Model No.
CHA161853
*ARI
Total cooling capacity (btuh)
178,000
*ARI
Standard
Total unit watts
20,300
Standard
360
EER (Btuh/Watts)
8.8
360
Ratings
Integrated Part Load Value
9.6
Refrigerant
Stage 1
Refrigerant
(22)
Stage 2
7 lbs. 9 oz.
(22)
Charge
Stage 3
7 lbs. 9 oz.
Blower wheel nominal diameter x width (in.)
18 x 18
Factory
Nominal motor horsepower
3
Evaporator
Factory
Installed
Maximum useable horsepower
3.45
Evaporator
Blower
Installed
**Drives
Voltage & Phase
208/230/460v3ph
Blower
and
**Drives
RPM Range
610 780
and
Drive
S ti
Factory
Nominal motor horsepower
5
Section
Factory
Installed
Maximum useable horsepower
5.75
Installed
**Drives
Voltage & Phase
208/230/460v3ph
**Drives
RPM Range
770 980
Evaporator
Net face area (sq. ft.)
16.0
Evaporator
Coil
Tube diameter (in.) & No. of rows
3/8 3
Coil
Fins per inch
13
Condenser
Net face area (sq. ft.)
30.5
Condenser
Coil
Tube diameter (in.) & No. of rows
3/8 2
Coil
Fins per inch
20
Diameter (in.) & No. of blades
(2) 26 4
Condenser
Air volume (cfm)
12,000 Total
Condenser
Fan(s)
Motor horsepower
(2) 1
Fan(s)
Motor watts
2200 Total
Condensate Drain Size mpt (in.)
1
No. & Size of filters (in.)
(4) 24 x 24 x 2
Electrical characteristics
208/230 to 460 volt 60 hertz 3 phase
*Rated in accordance with ARI Standard 360; 95
F outdoor air temperature and 80
F db/ 67
F wb entering evaporator air; minimum external duct static pressure.
**Using total air volume and system static pressure requirements determine from blower tables rpm and bhp required. Maximum usable hp of motors furnished
by Lennox are shown. If motors of comparable hp are used be sure to keep within the service factor limitations outlined on the motor nameplate.
OPTIONAL ACCESSORIES CHA161853 (Ordered Extra)
Unit Model No.
CHA161853
Model No.
ECH16185/275
Kw input range
1530456075
Electric
Heat
*F
208/230 volt (with 3 hp motor)
29H26
Heat
*Fuse
Block
208/230 volt (with 5 hp motor)
29H27
Block
460 volt
29H31
Roof Mounting Frame
RMF16185
(12H05)
Economizer Dampers with Gravity Exhaust No. & size of filters (in.)
REMD16M185
(40H14)
(2) 25 x 25 x 1
Differential Enthalpy Control
54G44
Model No
208/230 volt
PED16185
(12H16)
Power
Model No.
460 volt
PED16185
(12H17)
Power
Exhaust
Diameter (in.) & No. of Blades
(2) 16 5
Exhaust
Fans
(DownFlo Only)
Total air volume (cfm)
4200
(DownFlo Only)
Motor Horsepower
(2) 1/4
Watts Input (total)
500
Horizontal Supply and Return Air Kit (LB55756BD)
12H04
Ceiling Supply and
StepDown
RTD11185
(29G06)
Ceiling Supply and
Return Air
Diffusers
Flush
FD11185
(29G10)
Diffusers
Transition
SRT16185
(97H12)
Outdoor Air Dampers No. & size of filters (in.)
OAD16185
(12H03)
(1) 25 x 27 x 1
Automatic OAD16 Damper Kit
35G21
Low Ambient Control Kit (LB57113BK)
16J88
*Must be ordered extra. Factory installed heaters will have fuse block installed. Fuse block must be field installed in field installed heaters.
Содержание CHA16
Страница 47: ...Page 47 FIGURE 52 CYCLE CONTROL KIT WIRING DIAGRAM...
Страница 55: ...Page 55 NOTES...
Страница 58: ...C1diagram electromechanical thermostat with modulating economizer with D5 diagram Page 58...
Страница 60: ...C2 1 diagram electromechanical thermostat with modulating economizer and warm up with D5 diagram Page 60...
Страница 62: ...Page 62 B41 diagram with C1 diagram CHA16 2553 2753 3003 Operating Sequence...
Страница 64: ...Page 64 B9 diagram with C1 diagram CHA16 1853 Operating Sequence...