ELECTRICAL DATA CHA16823, 953, 1353 & 1603
ModelNo.
CHA16823
CHA16953
CHA161353
CHA161603
Linevoltagedata 60hz 3phase
208/230v
460v
208/230v
460v
208/230v
460v
208/230v
460v
Compressors
Ratedloadamps each
(total)
11.4/11.4
(22.8)
5.3/5.3
(10.6)
14.8/14.1
(28.9)
7.7/7.1
(14.8)
17.3/17.3
(34.6)
9.6/9.6
(19.2)
27.1/17.9
(45.0)
14.2/10.0
(24.2)
Compressors
(2)
Lockedrotoramps each
(total)
66/66
(132.0)
35/35
(70.0)
130/130
(260.0)
64/64
(128.0)
150/150
(300.0)
73/73
(146.0)
183/150
(333.0)
91/73
(164)
Condenser
Fullloadamps(total)
2.6
1.6
3.7
1.9
2.1/2.1
(4.2)
1.2/1.2
(2.4)
3.0/3.0
(6.0)
1.5/1.5
(3.0)
Condenser
FanMotor(s)
Lockedrotoramps(total)
5.9
3.3
7.3
3.7
5.1/5.1
(10.2)
2.7/2.7
(5.4)
6.2/6.2
(12.4)
3.4/3.4
(6.8)
Evaporator
Horsepower
2
2
2
2
2
3
2
3
3
3
Evaporator
Blower
Motor
Fullloadamps
7.5
3.4
7.5
3.4
7.5 10.6 3.4
4.8
10.6
4.8
Motor
Lockedrotoramps
41.0
20.4
41.0
20.4
41.0 58.0 20.4 26.8
58.0
26.8
**Recommendedmaximum fusesize(amps)
45
20
50
25
60
60
35
35
90
45
*MinimumCircuitAmpacity
36.0
17.0
44.0
23.0
51.0 54.0 28.0 29.0
69.0
36.0
Unitpowerfactor
.88
.88
.88
.88
.88
.88
.88
.88
.88
.88
*RefertoNationalElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements.
NOTE Extremesofoperatingrangeareplusandminus10%oflinevoltage.
**Wherecurrentdoesnotexceed100amps,HACRtypecircuitbreakermaybeusedinplaceoffuse.
ELECTRICAL DATA CHA161853, 2553, 2753 & 3003
ModelNo.
CHA161853
CHA162553
CHA162753
CHA163003
Linevoltagedata 60hz 3phase
208/230v
460v
208/230v
460v
208/230v
460v
208/230v
460v
Rated load amps
each
(3) 19.2
(3) 9.6
(2) 30.9
(2) 16.8
(2) 37.1
(2) 17.8
(2) 43.0
(2) 21.0
Compressors
Ratedloadamps
total
57.6
28.8
61.8
33.6
74.2
35.6
86.0
42.0
Compressors
Locked rotor amps
each
(3) 124
(3) 62
(2) 205.0
(2) 104.0
(2) 239.0
(2) 120.0
(2) 269.0
(2) 135.0
Locked rotor amps
total
372.0
186.0
410.0
208.0
478.0
240.0
538.0
270.0
Condenser
Full load amps(total)
9.6
4.8
9.6
4.8
9.6
4.8
9.6
4.8
Condenser
FanMotors (2)
Lockedrotoramps(total)
24.0
12.0
46.0
23.0
46.0
23.0
46.0
23.0
Evaporator
Horsepower
3
5
3
5
5
71/2
5
71/2
5
71/2
5
71/2 71/2 10 71/2 10
Evaporator
Blower
M t
Fullloadamps
10.6 16.7 4.8
7.6 16.7 24.2 7.6 11.0 16.7 24.2 7.6 11.0 24.2 30.8 11.0 14.0
Blower
Motor
Lockedrotoramps
58.0 91.0 26.8 45.6 105.0 152.0 45.6 66.0 105.0 152.0 45.6 66.0 152.0 193.0 66.0 84.0
Optional
(No.) Horsepower
(2) 1/4
(2) 1/4
(3) 1/4
(3) 1/4
(3) 1/4
(3) 1/4
(3) 1/4
(3) 1/4
Optional
Power Exhaust
F
Fullloadamps(total)
2.8
1.4
4.2
2.2
4.2
2.2
4.2
2.2
Power Exhaust
Fans
Lockedrotoramps (total)
6.5
3.3
8.7
3.9
8.7
3.9
8.7
3.9
**Recommended
max fuse size
Less exhaust fans
100 110
50
50
110 125
60
70
150 150
70
70
175 175
80
80
max. fusesize
(amps)
With exhaust Fans
100 110
50
50
125 125
70
70
150 150
70
70
175 175
80
80
Unit power factor
Less exhaust fans
.84
.84
.84
.84
.88
.88
.88
.88
.88
.88
.88
.88
.87
.87
.87
.87
Unit power factor
With exhaust Fans
.84
.84
.84
.84
.88
.88
.88
.88
.88
.88
.88
.88
.87
.87
.87
.87
*MinimumCircuit
Less exhaust fans
82.0 92.0 43.0 48.0 101.0 108.0 53.0 57.0 114.0 122.0 55.0 58.0 131.0 138.0 64.0 67.0
MinimumCircuit
Ampacity
With exhaust Fans
85.0 95.0 45.0 50.0 110.0 117.0 56.0 59.0 118.0 126.0 57.0 61.0 135.0 142.0 66.0 69.0
*RefertoNationalElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements.
NOTE Extremesofoperatingrangeareplusandminus10%oflinevoltage.
**Wherecurrentdoesnotexceed100amps,HACRtypecircuitbreakermaybeusedinplaceoffuse.
Содержание CHA16
Страница 47: ...Page 47 FIGURE 52 CYCLE CONTROL KIT WIRING DIAGRAM...
Страница 55: ...Page 55 NOTES...
Страница 58: ...C1diagram electromechanical thermostat with modulating economizer with D5 diagram Page 58...
Страница 60: ...C2 1 diagram electromechanical thermostat with modulating economizer and warm up with D5 diagram Page 60...
Страница 62: ...Page 62 B41 diagram with C1 diagram CHA16 2553 2753 3003 Operating Sequence...
Страница 64: ...Page 64 B9 diagram with C1 diagram CHA16 1853 Operating Sequence...