Page 32
CHA161853 MODELS (TABLE 8)
Electric Heat
Model No.
& Net Weight
No.
of
Steps
Volts
Input
kw
Input
Btuh
Output
*Total Unit &
Electric Heat
Minimum Circuit
Ampacity
& Net Weight
Steps
p
p
p
3 hp
5 hp
208
11.3
38,600
86.0
92.0
ECH16
1
220
12.6
43,000
ECH16
18515
208/230v
1
230
13.5
46,100
86.0
92.0
208/230v
(24H27)
460v
240
15.0
51,200
(
)
460v
(24H32)
(47 lbs )
440
12.6
43,000
(
)
(47 lbs.)
1
460
13.8
46,100
44.0
47.0
480
15.0
51,200
208
22.5
76,800
92.0
99.0
ECH16
**2
220
25.2
86,000
ECH16
185/30030
208/230v
**2
230
27.5
93,900
103.0
110.0
208/230v
(24H28)
460v
240
30.0
120,400
(
)
460v
(24H33)
(51 lbs )
440
25.2
86,000
(
)
(51 lbs.)
1
460
27.5
93,900
52.0
55.0
480
30.0
102,400
208
33.8
115,300
131.0
139.0
ECH16
**3
220
37.8
129,000
ECH16
185/30045
208/230v
**3
230
41.3
141,000
148.0
155.0
208/230v
(24H29)
460v
240
45.0
153,600
(
)
460v
(24H34)
(62 lbs )
440
37.8
129,000
(
)
(62 lbs.)
**2
460
41.3
141,000
74.0
78.0
480
45.0
153,600
208
45.0
153,600
170.0
177.0
ECH16
**4
220
50.4
172,000
ECH16
185/30060
208/230v
**4
230
55.1
188,000
193.0
200.0
208/230v
(24H30)
460v
240
60.0
204,800
(
)
460v
(24H35)
(67 lbs )
440
50.4
172,000
(
)
(67 lbs.)
**2
460
55.1
188,000
97.0
100.0
480
60.0
204,800
ECH16
185/300 75
440
63.0
215,000
185/30075
460v
(24H36)
**3
460
68.9
235,100
119.0
123.0
(24H36)
(88 lbs.)
480
75.0
255,900
*Refer to National Electrical Code manual to determine wire, fuse and disconnect size re
quirements. Use wires suitable for at least 167
°
F.
**May be used with two stage control.
NOTE Fuse block must be ordered extra. Factory installed heaters will have the
fuse block factory installed. Fuse block must be installed in field installed
heaters. See Optional Accessories tables.
CHA162553 MODELS (TABLE 9)
Electric Heat
Model No.
& Net Weight
No.
of
Steps
Volts
Input
kw
Input
Btuh
Output
*Total Unit &
Electric Heat
Minimum Circuit
Ampacity
& Net Weight
Steps
5 hp
7.5hp
208
22.5
76,800
110.0
117.0
ECH16
**2
220
25.2
86,000
ECH16
185/30030
208/230v
**2
230
27.5
93,900
110.0
118.0
208/230v
(24H28)
460v
240
30.0
102,400
(
)
460v
(24H33)
(51 lbs )
440
25.2
86,000
(
)
(51 lbs.)
1
460
27.5
93,900
55.0
59.0
480
30.0
104,400
208
33.8
115,300
139.0
148.0
ECH16
**3
220
37.8
129,000
ECH16
185/30045
208/230v
**3
230
41.3
141,000
155.0
163.0
208/230v
(24H29)
460v
240
45.0
153,600
(
)
460v
(24H34)
(62 lbs )
440
37.8
129,000
(
)
(62 lbs.)
**2
460
41.3
141,000
78.0
82.0
480
45.0
153,600
208
45.0
153,600
178.0
187.0
ECH16
**4
220
50.4
172,000
ECH16
185/30060
208/230v
**4
230
55.1
188,100
200.0
208.0
208/230v
(24H30)
460v
240
60.0
204,800
(
)
460v
(24H35)
(67 lbs )
440
50.4
172,000
(
)
(67 lbs.)
**2
460
55.1
188,100
100.0
104.0
480
60.0
204,800
208
56.3
192,200
217.0
226.0
ECH16
275/300 75
**5
220
63.0
215,000
275/30075
208/230v
(24H31)
**5
230
68.9
235,000
245.0
253.0
(24H31)
ECH16
185/300 75
240
75.0
255,900
185/30075
460v
(24H36)
440
63.0
215,000
(24H36)
(88 lbs.)
**3
460
68.9
235,000
123.0
127.0
480
75.0
255,900
ECH16
275/300 90
440
75.6
258,000
275/30090
460v
(24H37)
**3
460
82.7
282,000
145.0
150.0
(24H37)
(92 lbs.)
480
90.0
307,100
*Refer to National Electrical Code manual to determine wire, fuse and disconnect size re
quirements. Use wires suitable for at least 167
°
F.
**May be used with two stage control.
NOTE Fuse block must be ordered extra. Factory installed heaters will have the
fuse block factory installed. Fuse block must be installed in field installed
heaters. See Optional Accessories tables.
Содержание CHA16
Страница 47: ...Page 47 FIGURE 52 CYCLE CONTROL KIT WIRING DIAGRAM...
Страница 55: ...Page 55 NOTES...
Страница 58: ...C1diagram electromechanical thermostat with modulating economizer with D5 diagram Page 58...
Страница 60: ...C2 1 diagram electromechanical thermostat with modulating economizer and warm up with D5 diagram Page 60...
Страница 62: ...Page 62 B41 diagram with C1 diagram CHA16 2553 2753 3003 Operating Sequence...
Страница 64: ...Page 64 B9 diagram with C1 diagram CHA16 1853 Operating Sequence...