GeoBASIC Reference Manual
6. System Functions
TPS1100-Version 2.10
6-199
6.5.19 CSV_LockIn
Description
Starts the locking facility.
Declaration
CSV_LockIn( )
Remarks
If ATR is switched on then locking to the target will be done. If no
target available, then manual positioning will be started.
Parameters
none
Return Codes
AUT_RC_NOT_ENABLED
Theodolite without ATR or
lock status not set
AUT_RC_MOTOR_ERROR
Error at motor control.
AUT_RC_DETECTOR_ERROR
Error at ATR
AUT_RC_NO_TARGET
No target at the detection
range
AUT_RC_BAD_ENVIRONMENT
Bad environment at the
detection range (bad light…)
RC_NOT_IMPL
if ATR hardware is not
available
See Also
CSV_GetLockStatus,
CSV_SetLockStatus,
CSV_LockOut
Example
This example starts locking.
CSV_LockIn( )