GeoB
ASIC
Reference Manual
5.Standard Functions
TPS1100-Version 1.30
5-71
recovered value was not defined.
Example
Convert
dPresOldSys
from atmosphere to millibar.
DIM dPresOldSys AS Double
DIM dPresNewSys AS Double
DIM iOldsys
AS Integer
DIM iNewsys
AS Integer
'initialize values
iOldsys
= GM_ATMOS
dPresOldSys = 1.0
iNewsys
= GM_M_BAR
GM_ConvertPressure( iOldsys, dPresOldSys,
iNewsys, dPresNewSys )
5.6.30 GM_ConvertTemp
Description
Conversion of temperature from one system into the other.
Declaration
GM_ConvertTemp(
byVal iOldSys
AS Integer,
byVal dTempOldSys AS Double
byVal iNewSys
AS Integer,
dTempNewSys AS Double)
Remarks
This function is converting temperature-values from one standard
system into the other.
Note
Used formula: see Appendix, Geodesy Math. Formulas.