GeoBASIC Reference Manual
6. System Functions
TPS1100-Version 1.30
6-111
TMC_ANGLE_ERROR
Problems with angle res. incline sensor. A
valid angle could not be measured. Angle
data are not available.
At repeated occur call service.
TMC_BUSY
TMC resource is locked respectively
TMC task is busy. Angle data are not
available. Repeat measurement.
RC_ABORT
Measurement through customer aborted.
Example
Read the currently valid angle.
DIM Angles AS TMC_ANGLE_Type
DIM RetCode AS Integer
TMC_GetAngle( Angles, RetCode )
6.3.7 TMC_GetAngle_WInc
Description
Measure angles with inclination control.
Declaration
TMC_GetAngle_WInc(
iIncProg
AS Integer,
Angle
AS TMC_ANGLE,
iReturnCode AS Integer )
Remarks
The function measures the horizontal and vertical angle and in
dependence of the configuration, the inclination.
As far as no new measure program is started, the results can be
read. Additional to the normal return codes
iReturnCode
delivers also informational return codes, which will not interrupt
program execution.
Parameters
iIncProg
in
The manner of incline compensation.
Following settings are possible:
Incline Program Meaning
TMC_MEA_INC
get inclination
(apriori sigma)
TMC_
UTO IN
get inclination with
i
Содержание tps1100
Страница 1: ...GeoBASIC FOR TPS1100 User Manual Version 2 10 1997 2001 Leica Geosystems AG Heerbrugg Switzerland ...
Страница 150: ...GeoBASIC FOR TPS1100 Reference Manual Version 2 10 1997 2001 Leica Geosystems AG Heerbrugg Switzerland ...
Страница 411: ...GeoBASIC Reference Manual 6 System Functions TPS1100 Version 1 30 6 7 6 5 35 CSV_LibCallAvailable 6 213 ...
Страница 620: ...TPS1100 Version 2 10 6 1 ...
Страница 621: ......
Страница 623: ...TPS1100 Version 2 10 6 1 ...
Страница 624: ......
Страница 1053: ...TPS1100 Version 1 30 E 1 Appendix E GEOFONT ...
Страница 1154: ...GeoBASIC Reference Manual Appendix J List of Predefined Identifiers TPS1100 Version 1 30 J 9 TMC_SetOffsetDist 6 128 ...