GeoBASIC Reference Manual
6. System Functions
TPS1100-Version
1.30
6-106
Example
Start a distance measure, perform measure.
DIM iRetCode
AS Integer
DIM iWaitTime AS Integer
DIM Polar
AS TMC_Distance_Type
DIM lError
AS Logical
DIM lDone
AS Logical
'start distance measurement
ON ERROR RESUME
' to get valid angles
TMC_DoMeasure( TMC_DEF_DIST )
iWaitTime = -1
lDone
= FALSE
lError = FALSE
DO
'display measured values
TMC_GetPolar( iWaitTime, Polar, iRetCode )
SELECT CASE iRetCode
CASE RC_OK
'display all data
'e.g. set lDone here
CASE else
'handle error
lError = TRUE
END SELECT
LOOP UNTIL lError OR lDone
'stop distance measurement
TMC_DoMeasure( TMC_CLEAR )