GeoBASIC Reference Manual
6. System Functions
TPS1100-Version
1.30
6-90
BAP_SetPrism()
6.2.10 BAP_SetMeasPrg
Description
Set the distance measure program.
Declaration
BAP_SetMeasPrg( BYVAL iMeasPrg AS Integer )
Remarks
The
BAP_SetMeasPrg
routine sets the program for the distance
measurement.
Parameters
iMeasPrg
in
Distance measure program
Valid measure programs Meaning
BAP_SINGLE_REF_
STANDARD
Single measurement, with reflector,
standard speed
BAP_SINGLE_REF_
FAST
Single measurement, with reflector,
fast
BAP_SINGLE_REF_
VISIBLE
Single measurement, with reflector
and red laser
BAP_SINGLE_RLESS_
VISIBLE
Single measurement, reflectorless,
with red laser
BAP_CONT_REF_
STANDARD
Continuous measurement, with
reflector, standard speed
BAP_CONT_REF_FAST
Continuous measurement, with
reflector, fast
BAP_CONT_RLESS_
VISIBLE
Continuous measurement,
reflectorless, with red laser
BAP_AVG_REF_
STANDARD
Average measurement, with
reflector, standard speed
BAP_AVG_REF_
VISIBLE
Average measurement, with reflector
and red laser
BAP_AVG_RLESS_
VISIBLE
Average measurement, reflectorless,
with red laser
See Also
BAP_GetMeasPrg
Содержание tps1100
Страница 1: ...GeoBASIC FOR TPS1100 User Manual Version 2 10 1997 2001 Leica Geosystems AG Heerbrugg Switzerland ...
Страница 150: ...GeoBASIC FOR TPS1100 Reference Manual Version 2 10 1997 2001 Leica Geosystems AG Heerbrugg Switzerland ...
Страница 411: ...GeoBASIC Reference Manual 6 System Functions TPS1100 Version 1 30 6 7 6 5 35 CSV_LibCallAvailable 6 213 ...
Страница 620: ...TPS1100 Version 2 10 6 1 ...
Страница 621: ......
Страница 623: ...TPS1100 Version 2 10 6 1 ...
Страница 624: ......
Страница 1053: ...TPS1100 Version 1 30 E 1 Appendix E GEOFONT ...
Страница 1154: ...GeoBASIC Reference Manual Appendix J List of Predefined Identifiers TPS1100 Version 1 30 J 9 TMC_SetOffsetDist 6 128 ...