GeoBASIC Reference Manual
6. System Functions
TPS1100-Version
2.10
6-126
6.3.24 TMC_GetFace1
Description
Get face information of current telescope position.
Declaration
TMC_GetFace1( lFace1 AS Logical )
Remarks
This function returns the face information of the current telescope
position. The face information is only valid, if the instrument is in
an active measurement state (that means a measurement function
was called before the
TMC_GetFace1
call). Note that the
instrument automatically turns into an inactive measurement state
after a predefined timeout.
Parameters
lFace1
out
TRUE
: Face I
FALSE
: Face II
Return-Codes
RC_OK
Successful termination.
6.3.25 TMC_SetAngSwitch
Description
Defines the angle measurement correction switches.
Declaration
TMC_SetAngSwitch(
Switches AS TMC_ANG_SWITCH_Type )
Remarks
This procedure sets the angle measurement correction switches.
Note
No distance may exist for setting the angle switches. Call
TMC_DoMeasure( TMC_CLEAR )
before this
function.
Parameters
Switches
in
angular switches
Return-Codes
RC_OK
Successful termination.
TMC_BUSY
A distance exists
See Also
TMC_GetAngSwitch
Содержание tps1100
Страница 1: ...GeoBASIC FOR TPS1100 User Manual Version 2 10 1997 2001 Leica Geosystems AG Heerbrugg Switzerland ...
Страница 150: ...GeoBASIC FOR TPS1100 Reference Manual Version 2 10 1997 2001 Leica Geosystems AG Heerbrugg Switzerland ...
Страница 411: ...GeoBASIC Reference Manual 6 System Functions TPS1100 Version 1 30 6 7 6 5 35 CSV_LibCallAvailable 6 213 ...
Страница 620: ...TPS1100 Version 2 10 6 1 ...
Страница 621: ......
Страница 623: ...TPS1100 Version 2 10 6 1 ...
Страница 624: ......
Страница 1053: ...TPS1100 Version 1 30 E 1 Appendix E GEOFONT ...
Страница 1154: ...GeoBASIC Reference Manual Appendix J List of Predefined Identifiers TPS1100 Version 1 30 J 9 TMC_SetOffsetDist 6 128 ...