GeoBASIC Reference Manual
6. System Functions
TPS1100-Version
2.10
6-110
TMC_ACCURACY_
GUARANTEE
Accuracy is not guaranteed, because the
result consisting of measuring data which
accuracy could not be verified by the
system. Angle data are available.
You can a forced incline measurement
perform or switch off the incline.
This message is to be considers as info.
Return Codes
RC_OK
angle OK
TMC_ANGLE_ERROR
Problems with angle res. incline sensor. A
valid angle could not be measured. Angle
data are not available.
At repeated occur call service.
TMC_BUSY
TMC resource is locked respectively
TMC task is busy. Angle data are not
available. Repeat measurement.
RC_ABORT
Measurement through customer aborted.
Example
Read the currently valid angle.
DIM Angles
AS TMC_Angle
DIM iRetCode AS Integer
TMC_GetAngle_WInc(TMC_AUTO_INC, Angles,iRetCode)
6.3.8 TMC_QuickDist
Description
Measure slope distance and angles.
Declaration
TMC_QuickDist(
Angle
AS TMC_HZ_V_ANG_type,
Dist
AS Distance,
iReturnCode AS Integer )
Remarks
The function measures the horizontal and vertical angle and in
dependence of the configuration, the inclination.
The function waits until a new distance is measured and then it
returns the angle and the slope-distance, but no co-ordinates. Is no
Содержание tps1100
Страница 1: ...GeoBASIC FOR TPS1100 User Manual Version 2 10 1997 2001 Leica Geosystems AG Heerbrugg Switzerland ...
Страница 150: ...GeoBASIC FOR TPS1100 Reference Manual Version 2 10 1997 2001 Leica Geosystems AG Heerbrugg Switzerland ...
Страница 411: ...GeoBASIC Reference Manual 6 System Functions TPS1100 Version 1 30 6 7 6 5 35 CSV_LibCallAvailable 6 213 ...
Страница 620: ...TPS1100 Version 2 10 6 1 ...
Страница 621: ......
Страница 623: ...TPS1100 Version 2 10 6 1 ...
Страница 624: ......
Страница 1053: ...TPS1100 Version 1 30 E 1 Appendix E GEOFONT ...
Страница 1154: ...GeoBASIC Reference Manual Appendix J List of Predefined Identifiers TPS1100 Version 1 30 J 9 TMC_SetOffsetDist 6 128 ...