GeoBASIC Reference Manual
6. System Functions
TPS1100-Version 1.30
6-59
6.1.39 MMI_SwitchIconsBeep
Description
Switches measurement icons and special beeps on or off.
Declaration
MMI_SwitchIconsBeep( BYVAL lOn AS Logical )
Remarks
The function allows the switching (on/off) of the measurement
icons and special beeps (sector and lost lock).
Parameters
lOn
in
switches the icons and beep on or off
lOn
meaning
FALSE
no measurement icons and no
special beep
TRUE
the measurement icons will be
updated and the beeps are enabled.
This is the normal state during a
measurement dialog with continuos
measurements.
Return-Codes
RC_OK
Successful termination.
See Also
BAP_MeasRec
BAP_MeasDistAng
Example
The example uses the
MMI_SwitchIconsBeep
to disable the
icons and beeps.
MMI_
SwitchIconsBeep( FALSE )