GeoBASIC Reference Manual
6. System Functions
TPS1100-Version
1.30
6-104
Parameters
iWaitTime
in
delay time [ms] until a result is
available
=0
returns results with an already
measured distance.
>0
waits maximal the time
iWaitTime
for a result. If
iWaitTime
is chosen big
enough (e. g. 60000, which is
surely longer than the time-out
period of the device), the system
will wait for a result or until an
error occurs
<
0
Performs an automatic target
acquisition (if possible) and then
tries to measuring in a until a
valid result or an irrecoverable
error occurs. The value itself of
iWaitTime
is ignored.
Polar
out
point in polar co-ordinates
iReturnCode
out
see Additional Codes below
See Also
TMC_GetCoordinates
Additional Codes in
iReturnCode
RC_OK
measurement and values are OK
TMC_ACCURACY_
GUARANTEE
Accuracy is not guaranteed, because the
results are consist of measuring data
which accuracy could not be verified by
the system. Co-ordinates are available.
TMC_NO_FULL_
CORRECTION
The results are not corrected by all
active sensors. Co-ordinates are
available.
TMC_ANGLE_OK
Angle values okay, but no valid
distance. Co-ordinates are not available.
Содержание tps1100
Страница 1: ...GeoBASIC FOR TPS1100 User Manual Version 2 10 1997 2001 Leica Geosystems AG Heerbrugg Switzerland ...
Страница 150: ...GeoBASIC FOR TPS1100 Reference Manual Version 2 10 1997 2001 Leica Geosystems AG Heerbrugg Switzerland ...
Страница 411: ...GeoBASIC Reference Manual 6 System Functions TPS1100 Version 1 30 6 7 6 5 35 CSV_LibCallAvailable 6 213 ...
Страница 620: ...TPS1100 Version 2 10 6 1 ...
Страница 621: ......
Страница 623: ...TPS1100 Version 2 10 6 1 ...
Страница 624: ......
Страница 1053: ...TPS1100 Version 1 30 E 1 Appendix E GEOFONT ...
Страница 1154: ...GeoBASIC Reference Manual Appendix J List of Predefined Identifiers TPS1100 Version 1 30 J 9 TMC_SetOffsetDist 6 128 ...