6.2.13 BAP_SetHz
Description
Sets the horizontal angle to 0 or another given value.
Declaration
BAP_SetHz( BYVAL sCaptionLeft AS _Token )
Remarks
This procedure offers a dialogue which the user can complete in
order to influence the angular offset provided by the TMC
subsystem for the horizontal angle encoder. A button is provided
for setting the angle to zero, directly, or the user may prefer to
input another given value. Furthermore, the angle beep (at the
quarter circle positions from 0°) can be turned on and off.
Note
If the instrument is in Lock mode, then the instrument
tries to lock first before it sets the angle to 0.
Parameters
sCaptionLeft
Left caption text for dialog
See Also
Return Codes
RC_OK
Horizontal angular offset correct.
Example
Set the horizontal angle.
BAP_SetHz("BASIC" )