GeoBASIC Reference Manual
6. System Functions
TPS1100-Version 1.30
6-123
6.3.15 TMC_Get/SetAtmCorr
Description
Gets and sets the atmosphere part of distance measurement
corrections.
Declaration
TMC_GetAtmCorr ( AtmCorr
AS
TMC_ATM_TEMPERATURE_Type)
TMC_SetAtmCorr ( AtmCorr
AS
TMC_ATM_TEMPERATURE_Type)
Parameters
AtmCorr
out/in
Atmosphere
Return Codes
RC_OK
Completed successfully.
TMC_BUSY
TMC is in use and can not be changed.
Example
-
6.3.16 TMC_Get/SetHeight
Description
Gets and sets the current height of the reflector.
Declaration
TMC_GetHeight (
Height
AS Double )
TMC_SetHeight ( byVal Height
AS Double )
Parameters
Height
out/in
Height of reflector in Meters.
Return Codes
RC_OK
Completed successfully.
TMC_BUSY
measurement system is busy (no valid results)
Example
The example sets the reflectors height to the value of 1.0 m.
TMC_SetHeight ( 1.0 )
Содержание tps1100
Страница 1: ...GeoBASIC FOR TPS1100 User Manual Version 2 10 1997 2001 Leica Geosystems AG Heerbrugg Switzerland ...
Страница 150: ...GeoBASIC FOR TPS1100 Reference Manual Version 2 10 1997 2001 Leica Geosystems AG Heerbrugg Switzerland ...
Страница 411: ...GeoBASIC Reference Manual 6 System Functions TPS1100 Version 1 30 6 7 6 5 35 CSV_LibCallAvailable 6 213 ...
Страница 620: ...TPS1100 Version 2 10 6 1 ...
Страница 621: ......
Страница 623: ...TPS1100 Version 2 10 6 1 ...
Страница 624: ......
Страница 1053: ...TPS1100 Version 1 30 E 1 Appendix E GEOFONT ...
Страница 1154: ...GeoBASIC Reference Manual Appendix J List of Predefined Identifiers TPS1100 Version 1 30 J 9 TMC_SetOffsetDist 6 128 ...