15.9.1 Measuring the Pass Points
Start measuring the data as usual. After you have acquired all data from this tracker position
select
Move Station
from the standard toolbar or choose
Tracker
Move Station
. A wizard will
open.
If the wizard is opened for the first time, the page
Measuring the pass points
will appear. If
possible, measure
all
pass points which are accessible from this tracker position. For this, the
following elements are available:
ID
You can define what ID the next point to be measured will obtain.
Measure point
Use this button to measure a pass point with the T-Probe. When measuring, make sure that
the ID is correct and change it, if necessary.
From Scene
All points from the data explorer are inserted into the table.
Delete
Use this button to delete the currently selected pass points from the list.