5. SYSTEM SETTINGS
39
●
Silent: ON / OFF
Duration: 1 - 10 - 5000 (ms)
Turn the silent error detection on or off.
If you select ON, enter the duration. An error is detected when a value below the specified
mute level is received for longer than the specified duration.
●
FrameLocation
To be supported in the future.
●
Parity: ON / OFF
Turn the parity error detection on or off.
An error is detected when the parity bit of the input signal and the value calculated on the
LV 5837/LV 5838 are different.
●
Validity: ON / OFF
Turn the validity error detection on or off.
An error is detected when the validity bit of the input signal is inactive.
●
CRC: ON / OFF
Turn the CRC error detection on or off.
An error is detected when the CRC of the channel status bits of the input signal and the
value calculated on the LV 5837/LV 5838 are different.
●
Dolby CRC: ON / OFF (to be supported in the future)
Turn the Dolby CRC error detection on or off. This item appears during Dolby
measurement.