5. SYSTEM SETTINGS
34
F•2
5.6
Configuring the Meter Settings
To configure the meter settings, use the METER 1 tab.
These settings apply to the meters shown in the meter display, Lissajous display, and
surround display.
→
BEHAVIOR SETUP
→
NEXT TAB (×2)
→
Figure 5-7 METER 1 tab
●
Warning Index: -40 - -18 - 0 (dBFS)
Set the warning level. Meters are normally displayed in green, but they are displayed in red
if this value is exceeded.
●
Reference Index: -40 - -20 - 0 (dBFS)
Set the reference level. Meters are normally displayed in green, but they are displayed in
yellow when levels are between the Reference Index and Warning Index.
●
SCALE SETTING: dBFS / Nordic / DIN / BBC
Select the scale type.
[Reference] SCALE MAG → See section 6.2, “Configuring the Meter Display”
Table 5-1 Selecting the scale
SCALE MAG
OFF
ON
SCALE SETTING
dBFS
-60 to 0 dBFS
Reference Index ± 5 dB
Nordic
-42 to 12 dB
Reference Index ± 5 dB
DIN
-50 to 5 dB
Reference Index ± 5 dB
BBC
1 to 7 dB
Reference Index ± 1.25 dB
F•3
SYSTEM
USO
RESTRITO