5. SYSTEM SETTINGS
35
F•2
5.7
Configuring Loudness Settings
To configure the loudness settings, use the METER 2 tab.
The settings that you specify here apply to the loudness display.
→
BEHAVIOR SETUP
→
NEXT TAB (×3)
→
Figure 5-8 METER 2 tab
●
Measure Mode: BS1770-2 / ARIB / EBU / ATSC / CUSTOM
Select the integrated loudness measurement mode. The settings of each mode are shown
below. If you select CUSTOM, you can specify the values.
Table 5-2 Selecting the measurement mode
Measure Mode
BS1770-2
ARIB
EBU
ATSC
CUSTOM
Target Level
-24 (LKFS)
-24 (LKFS)
-23 (LUFS)
-24 (LKFS)
-99 to 0 (LKFS)
LFE Gain
0.0
0.0
0.0
0.0
0.0 to 10.0
BlockSize (ms)
400
400
400
400
200 to 30000
OverlapSize (%)
75
75
75
0
0 to 99
UpperThres
-
1
1
2
0 to 5
LowerThres
-
-1
-1
-2
-5 to 0
AbsoluteGating
ON
ON
ON
OFF
ON / OFF
Absolute Level
-70 (LKFS)
-70 (LKFS)
-70 (LUFS)
-
-99 to 0 (LKFS)
RelativeGating
ON
ON
ON
OFF
ON / OFF
Relative Level
-10 (LKFS)
-10 (LKFS)
-10 (LUFS)
-
-99 to 0 (LKFS)
●
SHORTTERM LOUDNESS: 200 - 3000 - 30000(ms)
Set the duration for calculating short-term loudness.
●
MOMENTARY LOUDNESS: 100 - 400 - 1000(ms)
Set the duration for calculating momentary loudness.
●
LOUDNESS RANGE
To be supported in the future.