Installation
Part No. 70476501ENR7
37
1 Manometer
2 Pressure Tap
3 Burner Tube Attaching Screws
4 Gas Valve Flange
5 Gas Valve
6 Specified Pressure
Figure 8
2. Remove gas valve:
a.
Remove the burner orifice(s) from the spud holder.
b.
When converting from Natural Gas to L.P. Gas, the
left-most burner and orifice (viewed from front) must
be removed.
c.
In place of the removed orifice, a blank orifice (Part
No. M400995) and a Burner Opening Cover (Part No.
M413099) must be installed.
3. Install the new, correct burner orifice(s). Refer to Figure 9
Burner Orifice and Table 1 . Torque each to 9 – 10 Nm.
4. Reinstall spud holder assembly to gas valve, making certain
burner orifice(s) are in line with burner tube opening. Refer
to Figure 9 Burner Orifice.
5. Commission tumble dryer for use.
NOTE: Blank burner orifices are Part No. M400995.
How to Adjust Gas Valve Governor/Regulator
1. Check gas burner orifice (manifold) pressure as follows.
2. Remove screw plug from pressure tap.
3. Connect a “U”-tube manometer (or similar pressure gauge)
to the burner orifice (manifold) pressure tap.
4. Start tumble dryer and note pressure once flame is burning.
Remove regulator cap and adjust regulator screw until the
burner orifice pressure per applicable table is achieved.
Replace regulator cap. Refer to Figure 8 .
5. Commission tumble dryer for use.
1 Size Stamped on Orifice
Figure 9 Burner Orifice
Содержание GA120L