Specifications and Dimensions
Part No. 70476501ENR7
13
Specifications
120 Series
170 Series
200 Series
Net Weight (approximate): Pounds (kg)
1,275 (578)
1,575 (716)
1,707 (774)
Gas Connection
Models through 3/10/13:
3/4 in. NPT
Models Starting 3/11/13:
1 in. NPT
1 in. NPT
1 in. NPT
Gas Burner Rating:
Btu/hr. (Mj/hr., kW)
270,000 (285, 79.13)
395,000 (417, 115.77)
425,000 (448, 124.56)
Steam Models
Net Weight (approximate): Pounds (kg)
1,375 (624)
1,675 (761)
1,807 (820)
Steam Connection
3/4 in. NPT inlet
3/4 in. NPT outlet
3/4 in. NPT inlet
1 in. NPT outlet
3/4 in. NPT inlet
1 in. NPT outlet
Steam Coil Rating at 100 psig:
Btu/hr. (kg/hr.) (recommended
operating pressure 80-100 psig)
405,000 (183.1)
648,000 (294.2)
648,000 (294.2)
Electric Models
Heating Element Rating: Kilowatts
(kW)
60 kW
Not Applicable
Not Applicable
NOTE: All machines are shipped with extra nipple to
convert to metric thread (from Standard).