Adjustments
Part No. 70476501ENR7
77
WARNING
The tumble dryer must not be operated if the airflow
switch does not operate properly. Faulty airflow
switch operation may cause an explosive gas
mixture to collect in the tumble dryer.
W072R1
IMPORTANT: Airflow switch vane must remain closed
during operation. If it opens and closes during the
drying cycle, this indicates insufficient airflow through
the tumble dryer. If switch remains open, or pops
open and closed during the cycle, the heating system
will shut off. The cylinder and fan will continue to
operate even though the airflow switch is indicating
insufficient airflow.
NOTE: To properly mount the airflow switch
bracket, or in case of a load not drying, the airflow
switch bracket may need to be checked for proper
alignment. Be sure the locator pins are securely in
their respective holes before tightening the bracket
mounting screws. This will assure proper alignment
of the airflow switch arm in the channel of the airflow
switch bracket and prevent binding of the arm.
Loading Door Switch
Loading door switch is factory preset, no field adjustment is
necessary.
Loading Door Catch (120 and 170
Series Models)
The door catch must be adjusted to have sufficient tension
to hold loading door closed against force of load tumbling
against it. Proper adjustment is when 7-15 pounds
(0.48-1.03 bar) pull is required to open door.
If adjustment is required, refer to Figure 44 and proceed
as follows:
1. Open door.
2. Loosen acorn nut.
3. Turn door strike screw in or out as required.
4. Tighten acorn nut.
1 Door Latch
2 Door Catch
3 Acorn Nut
Figure 44
Loading Door Strike (200 Series
Models)
The loading door strike must be adjusted to have sufficient
tension to hold loading door closed against force of
load tumbling against it. Proper adjustment is when
8-15 pounds (35.6-66.7 N) pull is required to open door.
If adjustment is required, refer to Figure 45 and proceed
as follows:
1. Open door.
2. Loosen adjustment screws.
3. Position strike for desired magnet engagement.
4. Retighten screws.