Electrical Requirements
58
Part No. 70476501ENR7
Serial Plate Rating
Terminal Block
Connections
Required
Rated Current*
(amps)
Breaker Rating
Recommended Wire
Size AWG (mm²)
* Current ratings vary slightly depending on model; refer to serial plate.
Table 8 For 120 Series Electric Tumble Dryer Models
Serial Plate Rating
Terminal Block
Connections
Required
Rated Current*
(amps)
Breaker Rating
Recommended Wire
Size AWG (mm²)
200-208/240V/60Hz/3ph L1,L2,L3 and ground
13.5
20A - 3 pole
12 (4)
380V/50 or 60Hz/3ph
L1,L2,L3 and ground
6.9
15A - 3 pole
14 (2.5)
400-415V/50Hz/3ph
L1,L2,L3 and ground
6.9
15A - 3 pole
14 (2.5)
440V/60Hz/3ph
L1,L2,L3 and ground
6.4
15A - 3 pole
14 (2.5)
460-480V/60Hz/3ph
L1,L2,L3 and ground
6.7
15A - 3 pole
14 (2.5)
* Current ratings vary slightly depending on model; refer to serial plate.
Table 9 For 170 Series Tumble Dryer Models
Serial Plate Rating
Terminal Block
Connections
Required
Rated Current*
(amps)
Breaker Rating
Recommended Wire
Size AWG (mm²)
200-208/240V/60Hz/3ph L1, L2, L3 and ground
14
20A - 3 pole
12 ( 4)
380V/50Hz/3ph
L1, L2, L3 and ground
8
15A - 3 pole
14 (2.5)
400-415V/50Hz/3ph
L1, L2, L3 and ground
8
15A - 3 pole
14 (2.5)
440V/60Hz/3ph
L1, L2, L3 and ground
7
15A - 3 pole
14 (2.5)
460-480V/60Hz/3ph
L1, L2, L3 and ground
7
15A - 3 pole
14 (2.5)