Operating Instructions
66
Part No. 70476501ENR7
Model
Pound (Kg)
200
200 (90.7)
DO NOT OVERLOAD.
NOTE: Overloading causes slow drying and
wrinkling.
b.
Close loading door. Tumble dryer will not operate with
the door open.
3. Determine Control Type and Temperature Setting
a.
Refer to the various controls and follow the instructions
for the appropriate control type.
b.
The type of fabric being dried will determine the
temperature setting. Consult the fabric care label or
fabric manufacturer to determine proper temperature
setting.
IMPORTANT: Always follow the fabric
care instructions supplied by the garment
manufacturer.
4. Remove Laundry
a.
When the cycle is complete, open door and remove the
laundry.
Reversing Operation
Tumble dryers with the reversing option prevent the tangling of
large pieces of laundry and minimize wrinkling. These tumble
dryers are equipped with a second motor and additional controls
which reverse the rotation direction of the cylinder.
Some models may have a switch or touchpad in the control panel
area so the operator can select the reversing or nonreversing
operation. In nonreversing mode, the cylinder will always turn
clockwise (as viewed from the front of the tumble dryer). If
the cylinder is turning counterclockwise when switched to
nonreversing, it will continue for a few seconds and then start up
in the proper direction. Refer to Programming Manual for more
information on reversing.
IMPORTANT: After any electrical maintenance is
done, make sure that the blower motor is turning
counterclockwise as viewed from the front. Then set
the reverse control switch to “nonreversing” and note
that the cylinder turns constantly clockwise as viewed
from the front of the tumble dryer. If not, interchange
L1 and L2 service leads to the reverse drive motor.
Control Instructions
Dual Digital Timer Control
RQ Control Suffix
1. Select HIGH, MED, LOW or NO HEAT by turning the
temperature knob.
HIGH
Temperature 190°F
(88°C)
MED
Temperature 170°F
( 77°C)
LOW
Temperature 120°F
(49°C)
Figure 24
2. Set the HEAT TIME for the number of minutes (from 0 -
60) desired.
Figure 25
3. Set the COOL DOWN TIME for the number of minutes
(from 0 - 15) desired.
Figure 26
4. Select reversing or nonreversing cylinder rotation setting, if
applicable.
Содержание GA120L