background image

Содержание 31-16222

Страница 1: ...bove 50 F for satisfactory operation of the dryer control system Preparing the Installation Site and Unpacking the Dryer 1 Prepare the area and exhaust for installation of the new dryer 2 Check to be sure that the existing external exhaust is clean and that it meets attached installation specifications 3 Using the four shipping carton corner posts as padding two on each side carefully lay the drye...

Страница 2: ...ct two HOT lines to outer screws L1 L2 of terminal block Connect NEUTRAL white line to center screw N of terminal block Tighten all terminal block screws firmly Properly secure power supply cable to strain relief Reinstall the cover _ I IL _IL I I _IIL _11_ qL IlL I _Li_mL I I I _ _ CAUTION FOR PERSONAL SAFETY d THIS APPLIANCE MUST BE PROPERLY j F GROUNDED Grounding If local codes permit be sure g...

Страница 3: ...em A combination of grease and lint creates a potential fire hazard o not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a poten tial fire hazard o not assemble ductwork with an fasteners that P extend into the duct These faste...

Страница 4: ...OM EXHAUST DIRECTLY ON CABINET NOTE Protect your hands and arms from sharp edges when working inside dryer cabinet Detach and remove the desired knockout Remove the screw inside the dryer exhaust duct end Keep the screw for step 5 Pull on the duct to remove it Cut the duct as shown Keep portion A Through the rear opening locate the tab in the middle of the dryer base Lift the tab to about 45 using...