1.5 POSITIONING AND FEET REGULATION
Place the blast chiller/freezer in a perfect horizontal position, acting if necessary on the
screw type adjustable feet. Use a spirit level to check it. The blast chiller/freezer must be
placed in order to operate properly and allow the correct defrost condensate water drai-
ning. In this way you will avoid noisy vibrations of the condensing unit. Check the correct
positioning of the condensate water basin and its draining.
1.6 INSTALLATION INSIDE YOUR SHOP/RESTAURANT /WORKROOM
We suggest you to install the blast chiller/freezer inside an air-conditioned room. We kindly remind you that
without this facility, malfunction may occur (for example condensation etc).
ATTENTION
In order to allow a good functioning of the blast chiller/freezer please draw attentions to the following in-
structions.
• Do not place the blast chiller/freezer to a direct exposure of sunlight and to all the other me-
ans of irradiation,
such as high intensity incandescent lights, cooking ovens, heating radiators.
• Do not place the blast chiller/freezer close to external exits into draught,
such as doors, windows,
air vent or air conditioning fans.
• Do not obstruct the blast chiller/freezer air inlet
.
• Do not place any kind of material on the blast chiller. Keep clear the whole blast chiller/freezer pe
-
rimeter in order to allow a proper air circulation.
• Do no place the blast chiller/freezer into an high relative humidity room
(condensate water cre-
ation is possible)
• Do not place the blast chiller/freezer inside a closed cavity.
Without a proper air circulation the
refrigeration unit will not work efficiently.
• Do not place hot trays or pans on the top of the blast chiller
.
Verify that in the installation room there is enough air turnover, even during closing and rest hours. In
this way the expansion/condensing unit will work correctly.
1.7 MINIMUM WALL DISTANCE
In order to allow a good blast chiller/freezer functioning and a correct air circulation, during the positioning you
have to respect some minimum wall distance as follows:
•
Keep a minimum distance, corresponding to the door opening length, from the front unit grid view.
•
Keep a minimum 10 cm distance of the blast chiller back from the wall.