LAUNCH
X-431 Torque 5 User Manual
89
measurement point to read the waveform measurement value.
There are two types of cursors: horizontal cursor and vertical cursor. The
horizontal cursor measures the value in the vertical direction, and the vertical
cursor can measure the value in the horizontal direction.
When set to ON, two horizontal/vertical reference lines named with Y1 & Y2/X1
& X2 will be displayed on the waveform display area. The user can use
/
or
/
to fine tune the line or drag the line directly to move it.
Tap
/
again to turn it off.
Note:
△
Reading: indicates the difference between the two cursor positions.
The voltage reading after Y1, Y2: indicates the position of the activated cursor in the
horizontal cursor relative to the zero level.
The time reading after X1, X2: indicates the position of the activated cursor in the
vertical cursor relative to the trigger point.
1/
△
X: Frequency.
7. Quick Save
This function is used to quickly save the currently running measurement
waveform. The oscilloscope can save waveform of analog channel or
mathematical channel to the local. Saved file format can be WAV or CSV.
The oscilloscope has two reference channels. WAV file can be uploaded to
reference channel for waveform reference. Relevant setup can be found in
“Menu”.