1. Connect the BNC connector of the BNC to 4mm test lead to the CH1/CH2
(select number of channel and channel No. according to actual situations).
2. Plug the black (GND) and red (SIGNAL) 4mm connectors into the Black
(GND) and other color (SIGNAL) banana sockets of the 6-way breakout
leads respectively.
3. Connect the black terminal and signal wire (its other end connected to the red
4mm connector) of the 6-way breakout lead to the GND and signal terminal
of the vehicle sensor.
11.7.2 Operations
1. Channel Selection
A total of 3 channels are available: CH1, CH2 and REF (reference channel).
Follow the methods to select a channel:
A. Tap the channel tab shown on the right edge of the screen.
B. Tap
to select the target channel. This method is only applicable to the
channel that is turned on.
Note: For better comparison and identification, each channel and waveform is
marked in different color.
The oscilloscope can display multiple waveforms simultaneously, but only one
waveform is allowed to display at top. The top channel is called current channel
displayed as
.
2. Channel Attributes & Trigger Setting
Channel attributes can be set via horizontal settings and vertical settings.
1). Horizontal Settings