2. Automatic Calibration
The automatic calibration routine lets you optimize the oscilloscope signal path
for maximum measurement accuracy. You can run the routine at any time but
you should always run the routine if the ambient temperature changes by 10°C
or more.
For accurate calibration, power on the DBSCar IX device and wait twenty
minutes to ensure it is warmed up. Calibration mainly includes simulation
channel calibration, trigger voltage of trigger circuit calibration and non-linear
calibration of horizontal base line deviation.
Note: During auto calibration, please make sure no signal in input terminal of CH1
/ CH2, otherwise it may damage device.
Tap
Menu -> User Settings
, then tap
Automatic Calibration.
Tap
OK
on the pop-up message box to start calibration. The Measurement LED
on the DBSCar IX device starts flashing and the prompt message “Calibrating,
please wait” will appear on the upper left corner of the screen.