The LAUDA device only supports USB sticks which are formatted with the
FAT32 file system. exFAT is not supported.
You can export the following files to the USB stick independently of each
other:
n
[Temperature graphic]
The data record is located in the subdirectory
LOGS
and contains the
file
LOG0.CSV
or several
.CSV files
with ascending numbering in
the case of multiple exports.
All temperature-time values from the graphics memory of the
device are exported.
n
[Device status]
This data record is located in the subdirectory
DEV_DATA
and con-
tains the file
DEV0.CSV
or several
.CSV files
with ascending
numbering in the case of multiple exports.
For example, the following are stored in this file:
Serial numbers
Software version
Hardware version
Running time
Various temperature values
Control parameters
Network settings
Error store
n
[Device data]
This data record is located in the subdirectory
DEV_DATA
and con-
tains the file
DAT0.CSV
or several
.CSV files
with ascending
numbering in the case of multiple exports.
All the existing measured values (temperatures, pressures, voltages, cur-
rents, and so on) are stored in this file as a snapshot of the system.
n
[Control parameters]
This data record is located in the directory
LAUDA / USER
and contains
the file
CTRLPARA.INI
. Only such a file can be exported. The file will
be overwritten on re-export.
The file contains all the temperature control parameters as well as the
temperature limits Tih and Til. The file is designed to transfer the settings
of the control parameters from one device to another.
n
[Analog module config.]
[Contact module config.]
These data records can only be exported if an analog module or con-
tact module has been connected to the constant temperature equip-
ment. The configuration is stored in the LAUDA / USER directory in
the
ANACFG.INI
or
CONTCFG.INI
file. Only such a file can be
exported in each case. This file will be overwritten on re-export. The file
contains the complete configuration of the connected analog module or
contact module. The file is designed to transfer the configuration from
one constant temperature device to another.
Personnel:
n
Operating personnel
1.
Insert the USB stick in the USB host on the operating unit of the
machine.
2.
Press the Enter key to open the menu.
Fig. 76: Example of a temperature graphic
LOG file
V6
Integral Process Thermostats and High-Temperature Thermostats
128 / 198
Содержание IN 1030 T
Страница 89: ...6 3 Menu structure Fig 45 Menu Part 1 V6 Integral Process Thermostats and High Temperature Thermostats 89 198 ...
Страница 183: ...Fig 99 Declaration of Conformity V6 Integral Process Thermostats and High Temperature Thermostats 183 198 ...
Страница 184: ...Fig 100 Declaration of Conformity V6 Integral Process Thermostats and High Temperature Thermostats 184 198 ...
Страница 186: ...V6 Integral Process Thermostats and High Temperature Thermostats 186 198 ...
Страница 187: ...V6 Integral Process Thermostats and High Temperature Thermostats 187 198 ...
Страница 199: ......