Table dip in the middle.
Note only adjust the table in very small steps over a period of time. Cast iron is a
very brittle material and will break if over stressed.
1
/ Lay an engineer’s straight edge across the table.
2
/ Using feeler gauges measure the gap under the straight edge.
3/
Remove the back panel to gain access to the underside of the machine.
4
/ Loosen the table clamp bolt in the middle of the table and tighten the table adjustment
bolt [jack]. Only move the bolts a very small amount.
5/
Check the amount that you have moved the table using the straight edge and the feeler
gauges.
6
/ Repeat until approximately ¾ of the dip is removed.
7
/ Leave for a few days and re-check. The cast iron will continue to move.
8/
Repeat until the dip is removed.
Troubleshooting
Poor cut.
1
/ Dull blade. Change the blade.
2
/ Bent tooth. Change the blade.
3
/ Wrong type of blade for the job.
4/
Scoring not adjusted correctly. [If fitted]
Saw will not start.
1
/ Check that the start switch is being depressed fully.
2
/ Check that the electrical power cord is plugged into the power outlet.
3
/ Check that the electrical supply is on [reset the breaker].
4
/ With the power disconnected from the machine, check the wiring in the plug is correct.
Check that the rubber insulation is stripped enough, and is not causing a bad connection.
Check that all the screws are tight.
5
/ With the power disconnected from the machine, check the wiring to the machine is
correct. Check that the rubber insulation is stripped enough and is not causing a bad
connection. Check that all the screws are tight
6
/ Check that you have the correct power 220V not 110V
7
/ Check the ground wire is wired correctly
The machine will not stop.
This is a very rare occurrence as the machine is designed to fail-safe. If it should occur
and you cannot fix the fault, seek professional assistance. The machine must be
disconnected from the power, and never run until the fault has been rectified.
1
/ Stop switch faulty. Replace the stop switch.
2
/ Internal
contactor faulty. Replace the contactor.
Содержание TS SERIES
Страница 2: ......
Страница 8: ...8 TSS floor plan TS floor plan...
Страница 45: ...45 Electrical circuit...
Страница 49: ...49 BODY WITH PANEL AND REMOVABLE PANEL TS...
Страница 51: ...51 BODY WITH PANEL TSS...
Страница 55: ...55 34 36 37 38 LU 00 00 00 Rip fence TS...
Страница 57: ...57 34 35 33 36 LUMF 00 00 00 Sliding table rip fence TSS...
Страница 59: ...59 LVC1219 00 00 00 CIRCULAR SAW MITER FENCE TSS 4 LONG...
Страница 61: ...61 LVC600 00 00 00 CIRCULAR SAW MITER FENCE OPTIONAL 2 LONG...
Страница 63: ...63 MF1270 03 00 00 00 SLIDING TABLE MF L 1270 TSS...
Страница 66: ...66 RC 00 00 00 T Scoring OPTIONAL TSS TS 44 45...
Страница 68: ...68 RCD 00 00 00 Scoring unit with DADO OPTIONAL TSS TS...
Страница 72: ...72 108 108 108 89 88 24 86 49 ST01 02 00 00 00 MAIN CIRCULAR SAW 1 PHASE MOTOR 2 2kW TSS TSS...