LAGUNATOOLS.COM
31
TROUBLESHOOTING
Motors
Symptom
Possible Cause
Solution
Motors do not start
1.
Main power cord(s)
un- plugged from
receptacle.
3 Circuit fuse blown or circuit
breaker tripped.
4. Conveyor motor fuse blown.
Plug in the primary power cord(s).
Replace fuse or reset
breaker (after determining
cause).
Replace fuse
Brush motor overloads.
1.
Inadequate circuit.
2.
Machine overloaded.
Check electrical
requirements
Use slower feed rate; slower
brush RPM; reduce depth of cut.
Conveyor motor oscillates.
1.
Motor not properly aligned.
2.
Shaft collar or bushing worn.
3.
Drive roller bent.
Loosen housing bolts, run
motor, retighten bolts.
Replace shaft collar or
bushing .
Replace drive roller.
Brush motor or conveyor
gear motor stalls.
1. Excessive depth of cut.
Reduce depth of cut;
decrease brush speed;
reduce feed rate.