StorView RAID Module
170
A user <
name
> has logged out
the Server from IP address:
<
IP_address
>.
Information
[0x106 (262)]
A specific user has
logged out of the
StorView Server from the
specified IP address
location. (The host name
was not available.)
No action required.
A user <
name
> has logged out
the Server from Host: <host
name>, IP Address:
<
IP_address
>.
Information
[0x107 (264)]
A specific user has
logged out of the
StorView Server from the
specified host and IP
address location.
No action required.
The multicast address is not
configured. No communication
will take place with other
servers.
Warning
[0x201 (513)]
The setting
“MulticastPort” is not
setup in the db/IP.db file.
The setting was removed
or the file became
corrupt.
Open the file <StorView
folder>\db\IP.db in a text
editor, and add the
following line:
MulticastPort=9191.
Save the file and start
StorView and press the
Rescan button or restart
the StorView service.
Multicast socket creation
failure: <reason>
Warning
[0x202 (514)]
StorView could not setup
the necessary
communication paths to
talk to other StorView
Servers. The specific
cause will be specified in
the <reason> appended
to the message.
Change the multicast port
used by StorView. Note
that all StorView servers
must communicate with
each other on the same
multicast port. If the
setting is changed on
one, they must be
changed on all StorView
Servers.
Multicast socket creation
failure: <reason> (continued)
Warning
[0x202 (514)]
StorView could not setup
the necessary
communication paths to
talk to other StorView
Servers. The specific
cause will be specified in
the <reason> appended
to the message.
Open the file <StorView
folder>\db\IP.db in a text
editor, and change the
following line:
MulticastPort=<port
number>. Save the file
and start StorView and
press the Rescan button
or restart the StorView
service.
StorView Server Event
Messages
Type [ID]
Cause
Action
Содержание 131018 - StorView Snapshot - Mac
Страница 1: ...StorView Storage Management Software RAID Module User Guide Part No 90254 01A Issue 1 0 March 30 2007...
Страница 28: ...StorView RAID Module 20...
Страница 34: ...StorView RAID Module 26...
Страница 76: ...StorView RAID Module 68...
Страница 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Страница 88: ...StorView RAID Module 80...
Страница 98: ...StorView RAID Module 90...
Страница 150: ...StorView RAID Module 142...
Страница 184: ...StorView RAID Module 176...
Страница 202: ...StorView RAID Module 194...
Страница 208: ...StorView RAID Module 200...
Страница 214: ...StorView RAID Module 206...