Quick Tour
15
2.1.3 Array and Logical Drive Section
Figure 2–4
Array and Logical Drive Section (RS-4835-F4-5404E Model Shown)
Array and Logical Drive Section Description and Condition
Array Status Icon
These icons are found in the Array section and depict the current
state of the specific component.
• Green - Status is ok.
• Yellow - Indicates a drive component in a RAID 1, 10, 5, 6 or
50 array has failed and the array is no longer fault tolerant, or
the array is in a rebuild cycle.
For RAID 6 arrays, it indicates 1 or 2 drives have failed. See
Drive Status Icon “Critical” state.
• Red - Indicates an array is invalid or offline due to an error:
RAID 0 = One drive has failed.
RAID 1/10 = Two drives have failed from the same pair.
RAID 5 = Two drives have failed.
RAID 6 = Three drives have failed.
RAID 50 = Two drives have failed within the same sub-array.
Green (Normal)
Yellow (Warning)
Red (Error)