1.4 - REPLACEMENT OF THE FUSE
Before starting to replace the fuse, try to find out the possible causes which could have
caused the break (short circuits in the power wires of the equipment, humidity, breakdown
of electronic components inside the equipment, etc.). Proceed with the replacement of the
fuse, using one having the same characteristics, after having identified the cause of the
break.
To replace the fuse, follow the operations described below.
1. Take a 3.15 Ampere, 5x20mm fast fuse.
If the equipment is supplied with the Power Outputs Connector, use a 10 Ampere,
5x20 mm fast fuse.
t
Warning:
disconnect the supply voltage and alarm cable before opening the case.
y
2. Unscrew the 8 fixing screws on the front panel using a 2.5 mm allen wrench and
open the case, taking special care with the internal connections of the equipment.
3. Identify the fuse holder on the printed circuit board (see Figure 3).
4. Remove the fuse holder cap and replace the fuse.
5. Replace the fuse holder cap and close the case, paying special attention to avoid
crushing the connecting wires.
6. Screw the 8 fixing screws to the front panel.
Figure 3