4.10 - SKIP TO INGREDIENT/UNLOAD
During the execution of a Recipe, this Function allows users to not execute
the Ingredient/Unload appearing on the display but to select the desired
one, thereby executing the Recipe without following the order in which the
Ingredients/Unloads are memorized.
•
Recipe Execution.
1. To select the Ingredient/Unload that follows the one appearing on the
display, press the
q
key. To select the Ingredient/Unload that precedes
the one appearing on the display press the
z
key.
•
If the Feed Refusal Adjustment Function is enabled, only Ingredients that
come after the one appearing on the display can be selected.
4.11 - TARGET WEIGHT RESTORE
During the execution of a Recipe, this function restores the programmed
value of the Ingredient/Unload as it appears on the display.
This Function is greatly useful when, without having performed any
loading or unloading operations, the weight that appears on the display
has changed with respect to the programmed value. This may occur, for
example, when the Weight Block Function is not used when moving the
mixer wagon during loading or unloading operations. In this case, to view
the exact weight to load or unload on the display, use the Target Weight
Restore Function before resuming weighing operations.
•
Recipe Execution.
1. Press the
Man./Zero
key for 3 seconds. The [
RESET
] message will
appear on the display.
2. When the [
RESET
] message disappears, release the key. The
equipment is ready to continue the previously interrupted operations.
•
This Function is not available during the Prealarm and Queue Time
phase.